NWCG Guide for Wildland Fire Modules
Guides & ReferencesGuide / reportOn this site
Reference guidance on NWCG Guide for Wildland Fire Modules. Use it to support agency planning and professional discussion. Review local applicability and select specific actions, responsibilities, and follow-up measures.
- Source / publisher
- National Wildfire Coordinating Group
- Jurisdiction
- United States unless publisher specifies otherwise
- Published
- May 2025
- Edition
- May 2025
- Date evidence
- publisher catalog current edition month: 2025-05 · where we read it (opens in a new tab)
Read the document
Text of the publisher's document, reproduced under the rights recorded on this page (Explicit NWCG public-domain notice in the publication: copying permitted with accurate credit to NWCG; the NWCG logo may not be used.). Tables, figures and layout may not reproduce; the unchanged PDF above is the authoritative copy.
NWCG Guide for Wildland Fire Modules
Source: National Wildfire Coordinating Group.
Original document: NWCG Guide for Wildland Fire Modules.
Publisher page: NWCG publication.
Edition: 2025-05. Retrieved: 2026-10-05.
Rights: the publication states that NWCG publications and training materials are public domain and copying is permitted with accurate credit. NWCG logo restrictions still apply.
SHA-256 of original PDF: 0dbb26afa59f5332d45ad6640d1e3ae20df254ba5be47ed6e58d6aa7c6d15f20.
This is a full page-by-page text extraction. Tables, diagrams, formatting, and image-only content may not reproduce correctly; use the unchanged PDF for authoritative layout. No abridgment was intentionally made.
Page 1
A publication of the National Wildfire Coordinating Group NWCG Guide for Wildland Fire Modules PMS 431 MAY 2025 NFES 002641
Page 2
The National Wildfire Coordinating Group (NWCG) provides national leadership to enable interoperable wildland fire operations among federal, state, Tribal, territorial, and local partners. NWCG operations standards are interagency by design; they are developed with the intent of universal adoption by the member agencies. However, the decision to adopt and utilize them is made independently by the individual member agencies and communicated through their respective directives systems. NWCG Guide for Wildland Fire Modules May 2025 PMS 431 NFES 002641 The NWCG Guide for Wildland Fire Modules is a supplemental guide for wildland fire module operations containing information frequently used in the field. It is not intended to replace existing publications, including the NWCG Incident Response Pocket Guide (IRPG), PMS 461, https://www.nwcg.gov/publications/pms461, NWCG Standards for Wildland Fire Module Operations, https://www.nwcg.gov/publications/pms430, among others.
Page 3
NWCG Guide for Wildland Fire Modules i Table of Contents Operations ................................................................................................................................................. 1 Chief of Party Checklist ......................................................................................................................... 1 Fireline Leader Responsibilities ............................................................................................................. 2 Chainsaw Use ......................................................................................................................................... 4 Portable Pump Operating Instructions ................................................................................................... 7 Structure Protection Tips ....................................................................................................................... 8 Basic Cabin Protection Order............................................................................................................... 10 Structure Wrap – Tips and Considerations .......................................................................................... 11 Remote Operations ............................................................................................................................... 12 Longline Remote Hook Setup .............................................................................................................. 14 Radios ....................................................................................................................................................... 15 KNG-P150S Portable Radio ................................................................................................................ 15 BKR 5000 Portable Radio .................................................................................................................... 16 Bendix King DPHX (Legacy) Portable Radio ..................................................................................... 22 Mapping ................................................................................................................................................... 27 Township/Range/Section System of Land Measure ............................................................................ 27 Converting Latitude/Longitude ............................................................................................................ 28 Area and Distance Conversion Charts ................................................................................................. 29 Declination Map ................................................................................................................................... 30 Avenza and Mobile Mapping Guide .................................................................................................... 31 Weather and Fire Behavior .................................................................................................................... 32 Cloud Types ......................................................................................................................................... 32 Wind Adjustments for Exposure of Fuels to Wind .............................................................................. 34 Rate of Spread Estimation .................................................................................................................... 35 Sling Psychrometer Use ....................................................................................................................... 36 Fuel Moisture Sampling ....................................................................................................................... 37 Fuel Models .......................................................................................................................................... 40 Relative Humidity and Dew Point Tables ............................................................................................ 45 Fine Dead Fuel Moisture ...................................................................................................................... 68 References ................................................................................................................................................ 73 Western Air Ambulance Phone List ................................ .................................................................... 73 Air to Ground Frequency Reference Map ............................................................................................ 75 Slope ..................................................................................................................................................... 76
Page 4
NWCG Guide for Wildland Fire Modules 1 of 76 Operations Chief of Party Checklist General • Safety of the group is your paramount responsibility. • Accept your role as the leader. • Be fire ready at any time. • Work hard. • Be safe. Mobilization • Obtain resource order and make copies. • Update crew manifest and make copies. • Update crew qualifications sheet and make copies. • Document accountable property (radios, laptops, etc.). • Download GPS maps for assignment location and obtain paper maps if possible. • Record starting mileage for vehicles. • Plan travel route and Estimated Time of Arrival (ETA). • Make hotel reservations as necessary. • Coordinate with the incident/requesting unit regarding necessary supplies (food, backcountry gear, etc.). • Make copies of the following for the fire office: manifest, travel authorization, travel route, ETA. • Coordinate further with incident/requesting unit while in transit. At Assignment • At check-in: notify home unit of arrival. • Provide manifest and time records to overhead. • Obtain radio frequencies and program by hand or computer. • Obtain specific information regarding assignment (sleeping arrangements, food, etc.). • Attend all operational briefings. • Fill out and submit signed Crew Time Reports (CTRs), SF 261 daily. • Pass along updates regarding progress, changes, and status. • Plan early for logistical needs – place orders for the following shift by 1300. • Log chainsaw use and maintenance.
Page 5
NWCG Guide for Wildland Fire Modules 2 of 76 • Fill out and submit Activity Log (ICS 214) and other required documentation. • After Action Review (AAR) every shift. Check-Out • Verify that times on CTRs match times on Incident Time Reports (OF 288) for each person. • Don’t depart without signed OF 288 in hand. • Make copies of all reports, assignments, photos, and maps. • Obtain Supply (S) numbers for all equipment to be replaced. • Obtain and review crew evaluations. • Notify home unit and dispatch of departure and travel plans. • If moving between incidents, start time = departure time from first incident. Return to Station • Notify duty officer and dispatch of return. • Tell dispatch to change status in the Interagency Resource Ordering Capability (IROC) for rest and recuperation (R&R) and module availability. • Fuel all vehicles. • Fill out mileage forms. • Clean inside and outside of vehicles. • Disinfect all food containers, cooking equipment, and water coolers. • Rehab and log all chainsaws, tools, pumps, etc. • Ensure all module gear and vehicles are fire ready before departure. • Restock fire monitoring kits. • Fill out fire report and make copies for home unit. • Update fire folders with the following: fire and other reports, trip manifest, resource order, CTRs, maps, relevant Incident Action Plans (IAPs), travel documentation, crew evaluation, incident replacement requisitions. • Provide documentation for home unit: time records, fire reports, crew evaluations, travel sheets, mileage forms. Fireline Leader Responsibilities • Establish a clear leader’s intent and supervise at the scene of action, not in your truck or office. Initial Attack Incident Commander (ICT4/5) • Provide for safety and welfare of assigned personnel. • Initiate and maintain Incident Briefing (ICS 201). • Size up fire situation and concisely communicate resource needs.
Page 6
NWCG Guide for Wildland Fire Modules 3 of 76 • Analyze incident complexity. • Plan appropriate method of attack. • Brief personnel and keep them informed. • Direct and coordinate assigned resources. • Monitor weather, fire behavior, and environmental factors to anticipate changes. • Adjust tactics to meet changing conditions. • Maintain current Activity Log (ICS 214). • Solicit feedback and facilitate AARs. Task Force/Strike Team Leader • Obtain briefing from Division/Group Supervisor (DIVS)/ Incident Commander (IC). • Review assignment with assigned resources. • Travel to and from line with assigned resources. • Monitor and inspect progress; make changes as necessary. • Coordinate actions with adjacent resources. • Keep supervisor informed of status and progress. • Obtain logistics/equipment needs from assigned resources. • Retain control of assigned resources while off the fireline. • Maintain a current Activity Log (ICS 214). Single Resource Boss (Crew Boss [CRWB], Engine Boss [ENGB], Firing Boss [FIRB], Felling Boss [FELB]) • Supervise and direct a firefighting module (hand crew, engine, dozer, firing team, or fallers). • Obtain briefing from Task Force/Strike Team Leader/IC. • Review assignment with module and assign work tasks. • Obtain necessary equipment and supplies. • Review current and predicted weather conditions and expected fire behavior. • Brief module on safety, including escape routes and safety zones. • Monitor work progress; make changes as necessary. • Keep supervisor informed of progress and changes. • Inform supervisor promptly of any issues. • Brief/debrief with relief personnel on the fireline. • Complete and turn in time records.
Page 7
NWCG Guide for Wildland Fire Modules 4 of 76 Chainsaw Use Use caution when making chainsaw carburetor adjustments. Instructions below are intended for those who are experienced saw tuners. If you are unfamiliar with these procedures, seek out someone who is. • If your saw fails to start, check the following: o Gas (50:1). o On/off switch is turned ON. o Spark plug has spark. o Exhaust screen is clean. o Air filter is clean. o Jets are adjusted correctly: Never over-tighten jets! Turn both jets to the right (clockwise) until snug. Then turn back to the left (counterclockwise) until desired setting. Stihl: high 3/4 turn, low 1/4 turn. o Carburetor is flooded: Tighten high jet until snug. Pull starter cord until saw starts. Loosen high jet to correct setting. • Jet and idle field adjustments: o Clean or replace air filter. The carburetor cannot be properly tuned unless the air filter is clean and in good condition. o Run saw at full throttle. Turn HS screw in (clockwise) slowly. As the HS screw is turned in, saw is being leaned out (more air, less gas). Keep leaning as long as the saw flutters. Go until flatline (no flutter) and back off. o Release throttle and let saw idle. If saw idles too fast (chain turning) or too slow (saw dies), adjust idle screw only. Turn screw counterclockwise to stop chain or clockwise if saw dies. o Idle for 30 seconds. Do the dump/roll test. Saw should idle in all positions. If saw fails the dump test, tighten (turn clockwise) the LS screw a quarter turn. Fuel is pooling and flooding the engine. Repeat. o Throttle up saw. It should immediately respond. If it stutters, the LS is too lean. Back out (counterclockwise) the LS screw a quarter turn or less. Repeat until saw revs immediately. Adjust idle and repeat steps as needed. o Tune the tachometer. High RPMs should be 13,500 or less. Idle RPMs should be around 2,500. • Purging Instructions: o Drain fuel tank.
Page 8
NWCG Guide for Wildland Fire Modules 5 of 76 o Run saw until it stops. o Attempt restarting with choke on until saw fails to ignite. o Remove fuel tank cap and invert saw for 5 minutes. o Remove spark plug. o Pull starter cord until piston is at lowest point in cylinder. o Spray WD-40 into cylinder and pull cord a few times. o Replace cap and plug. COMMONLY REPLACED STIHL PARTS Part Description Stihl Manufacturer Part Number E clip 9460 624 0801 7 tooth Rim Sprocket 0000 642 1223 Sprocket Washer 0000 958 1032 HD Air Filter 0000 120 1654 Fuel Filter/Pick up body 0000 350 3504 Spark Plug (NGK) BPMR 7 A Spark Plug (Bosch) WSR 6 F Round File, box of 1 dozen 5605 773 5512 91 Driver Full Skip Chisel Chain 3/8" Pitch,.050" gauge 33RSF (specify number of drivers) 28” bar, Rollomatic ES wide tip 91 drivers, 3/8" pitch,.050" gauge 3003 000 9638 STIHL BARS 3/8” pitch .050” gauge Length Drivers 25” 84 28” 91 32” 105 36” 114 2-CYCLE MIX QUANTITIES (Ounces) Gasoline Quantity Mix 0.5 gal 1.0 gal 2.0 gal 2.5 gal 5.0 gal 16:1 4.0 8.0 16.0 20.0 40.0 24:1 2.7 5.4 10.7 13.4 27.0 32:1 2.0 4.0 8.0 10.0 20.0 40:1 1.6 3.2 6.4 8.0 16.0 50:1 1.3 2.6 5.2 6.4 12.8
Page 9
NWCG Guide for Wildland Fire Modules 6 of 76 MIXING GUIDE – 3:1 SLASH MIX, 5 GALLON CAN TACHOMETER RPM GUIDE Model Idle High Stihl MS360 2800 13500 Stihl MS440 2500 13500 Stihl MS460 2500 13500 Stihl MS660 2500 13500 Husqvarna 372XP 2700 13500 Husqvarna 385XP 2700 12500 CONVERSIONS 1 cup 8 oz 1 pint 2 cups 16 oz 1 quart 2 pints 4 cups 32 oz .946 L 1 gallon 4 quarts 8 pints 16 cups 128 oz 3.785 L 8.33 lbs* *applies only to water weight; fuel will weigh less Number of Cans 3 parts diesel fuel Stop Pump @__gal 1 part gasoline Stop Pump @__gal 1 3.75 1.25 2 7.50 2.50 3 11.25 3.75 4 15.00 5.00 5 18.75 6.25 6 22.50 7.50 7 26.25 8.75 8 30.00 10.00
Page 10
NWCG Guide for Wildland Fire Modules 7 of 76 Portable Pump Operating Instructions Fuel • Use 24:1 mix (27 ounces of oil per 5 gallons of gasoline) for 2 stroke engines. • Some pumps may be 4 stroke engines which take straight gas. Double check fuel requirements! • Fuel consumption: Mark III 5 gallons per 3 hours, Shindaiwa 5 gallons per 10 hours. • Connect fuel can line to tank with quick connect valve. Loosen lid on tank for venting. Cautions • Do not run engine at full speed until it is thoroughly warmed up (at least 1 minute idling). • Do not run engine with pump disconnected. • Do not run pump dry. • Do not use suction hose without foot valve strainer. • Remove and drain pump after final use, and at night if temperatures are below freezing. Setting Up and Starting Mark III Pumps • Connect fuel line to pump and fuel can as specified above. • Connect suction hose to pump. Be sure to connect foot valve to male end of suction hose. Make sure rubber gasket or washer is in place before attaching female end to pump. Tighten firmly with spanner wrench. Put foot valve inside canvas bucket from pump kit, and/or use rope or a float to keep strainer from being too close to water surface or resting on the bottom in the mud. • Attach wye valve to discharge side of pump. Hand-tighten only. Twist priming pump onto one leg of the wye and hose on the other. Close valve to the hose, leaving primer valve open. Stroke priming pump until water squirts out the small holes, or until resistance is too great to continue. After priming, close valve to primer and open valve to hose. • Pull the decompression switch out until it comes to a “click” stop (newer pumps lack these switches). • Put the choke on START if the engine is cold. • Move throttle to START AND WARM UP position. • Give starter rope several quick, steady pulls until engine starts or pops. Turn choke off immediately after engine makes any noise to prevent flooding on the next pull. • Put choke on RUN and pull engine over until it starts (usually 1 to 3 pulls). • Push decompression switch in fully as soon as engine starts. • Allow engine to warm up fully (hot to the touch) before using full throttle. • If the pump shuts down automatically, you may need to reset the automatic cutout by pushing in on the reset rod (yellow circular wire located below stop switch).
Page 11
NWCG Guide for Wildland Fire Modules 8 of 76 Stopping a Mark III Pump • Move throttle lever to STOP position. • Let pump run for about two minutes in this position. • Press and hold stop switch until engine is fully stopped. Ordering Pumps • Order two pump kits (NFES 0870) for redundancy. • Hose: 100 feet of 1” laterals for every 200 feet of 1 ½” trunk line. • Remember to order hardware as well: gated wyes, nozzles, hose clamps, reducers, etc. Structure Protection Tips • Identify fire hazards that need to be mitigated to protect cabin: o Is the roof clear? o Are the eaves clear? o Are there building materials or firewood stacked against the cabin? o Are there trees, snags, or other vegetation that pose a direct hazard to the cabin? • Sprinkler system setup tips: o Sprinkler coverage should wet all surfaces of structure. o Sprinklers at the corners provide ideal coverage. o Vary heights to provide improved coverage. o Set two sprinklers at opposite corners above the roof line and the other two below the roof line. o Adjust sprinklers for long range (spray) or short range (mist). • Sprinkler head attachment methods: o Set sprinkler heads on poles, tripods, or stands to get them above ground/cabin. Sprinkler placement on a structure.
Page 12
NWCG Guide for Wildland Fire Modules 9 of 76 Saw cuts for sprinkler attachments. Notches prevent sprinklers from rotating when hose is charged. • Pumps: o Shindaiwa pumps work well close to water sources. o Use 5-gallon can and fuel line attachment from sprinkler kit for Shindaiwa pumps. o Mark III pumps work well when the structure is far from, or high above the water source. • Miscellaneous: o Use extra sprinklers on wood piles or surrounding fuels. o Make sure your hose lay is protected. o Take the extra steps necessary to prevent water from entering the structure.
Page 13
NWCG Guide for Wildland Fire Modules 10 of 76 Basic Cabin Protection Order • 1 pump kit (NFES 0870) • 1 sprinkler kit (NFES 0920 or NFES 1048) • 700 feet of 1” hose (NFES 7273) • 10 gallons of premixed fuel (NFES 7358) Sprinkler Kit Contents (NFES 1048) Cache Item Qty Description 0010 1 REDUCER – 1 1/2" NH-F (9 TPI) TO 1" NPSH-M (11 1/2 TPI) 0136 1 NOZZLE – GARDEN HOSE, 3/4" NH, ADJUSTABLE, BRASS 0137 1 NOZZLE – PLASTIC, 60 GPM, 1 1/2'' NH-F X 4 3/4'' LONG 0235 1 WRENCH – SPANNER, 11", 1 1/2" TO 2 1/2" HOSE SIZE 0321 1 HAMMER – CLAW 0394 12 TIE WRAPS – ONE WAY, 15" – 17" 0402 4 REGULATOR – WATER PRESSURE, R.V.,40-50 PSI, 3/4" M/F-H BRASS 0473 1 WRENCH – ADJUSTABLE, 10" 0538 12 PIN – PANEL, HOLD DOWN, 8" LONG 0721 5 GASKET – GARDEN HOSE, 3/4" 0729 1 FORM, – INSTRUCTIONS SPRINKLER KIT 0731 4 TEE – HOSELINE, 1 1/2" NH-F X 1 1/2" NH-M X 1" NPSH-M W/CAP 0733 4 REDUCER – 1'' NPSH-F (11 1/2 TPI) TO 3/4'' NH-M (11 1/2 TPI) 0744 1 PACKSACK – WATERPROOF, W/STRAPS 0808 1 CARTON – FIBERBOARD, 16" X 14" X 12", DOUBLE WALL W/HAND HOLDS 0824 2 BLOCK – WOOD, 2" X 4" X 6" 0835 4 VALVE – SHUT OFF, BRASS, BALL, 3/4" NH 0882 1 NAILS – DUPLEX, DOUBLE HEAD, 16D, 3" 0904 2 VALVE – WYE, GATED, BRASS, 3/4" NH-F X 3/4" NF-M X 3/4" NH-M 0913 8 STAKE – W/CLAMP, SPRINKLER, METAL, 18" X 1" X 1" 0937 1 SAW – PRUNING, 10" 0999 4 SPRINKLER ASSEMBLY – 1/2", SPRINKLER HEAD W/COUPLINGS 1016 5 HOSE – GARDEN, SYNTHETIC, 3/4" NH X 50' 3305 2 CORD – NYLON, 1/8'' X 100' 3318 1 BAG – COTTON, LUNCH OR TOOL, 10'' X 24''
Page 14
NWCG Guide for Wildland Fire Modules 11 of 76 Structure Wrap – Tips and Considerations • Structure wrap (NFES 0881) comes in 54” x 300’ rolls (1350 square feet). • Suggested order list: o Ladders (minimum of 2) tall enough to reach peak of roof. o Staplers and staples (order extra). o Scissors. o Needle-nose pliers. o Permanent markers. o 3” aluminum tape (available in rolls of 360’). • Considerations: o Take some time to plan. o Start from the bottom of the building so your seams don’t catch embers. o Consider likely wind and fire front direction when deciding how to overlap vertical seams. o Using aluminum tape on seams should reduce the number of staples needed. o Draw windows on outside of wrap to prevent breaking them in the process of wrapping and unwrapping. o Can you safely work on the roof if necessary? Will it support your weight? Are there other options? o Will you still need access to the inside of the building? o Consider future removal of structure wrap when deciding how many staples to use.
Page 15
NWCG Guide for Wildland Fire Modules 12 of 76 Remote Operations • When providing an update on a remote portion of a fire, managers may have specific questions and will usually share them with you. If not, the items listed below will assist you in painting a picture of ongoing fire status: o Estimated (or known) current fire size. o Growth overnight or since last checked. o Percent active perimeter. o Active portion or quadrant (north, south, east, west). o Fuel model carrying fire (note fuel model transitions in particular). o Observed fire behavior: rate of spread, flame length, torching, spotting, smoke observations. o Time of activity (burning window). o Weather highlights: highest temperature, lowest relative humidity, wind speed, and direction. o Communicate your plan for the shift. o Ask if any other information is needed (time of next required update, etc.). o Specific safety or operational concerns and mitigations. • When communicating with a dispatch center or incident command post, consider additional communication standard operating procedures: o Notify dispatch when you begin your travel to and from the fire, when you begin driving and when you begin hiking. This may be redundant but err on the side of too much information rather than not enough. o Let dispatch know when you’ve arrived on the fire and give them an estimate of when you’ll provide a fire update. o Communicate your info only when it is appropriate to do so. If other radio traffic exists, wait patiently for a break in radio traffic, and be only as a detailed as necessary with your update. o Always be cordial and polite when communicating with dispatch centers.
Page 16
NWCG Guide for Wildland Fire Modules 13 of 76 One Day Order Amounts Use the following estimates to order enough supplies for one day on the fireline: Item Quantity Water, 5-gallon cubie ½ per person MREs 4 per person Batteries, AA 16 per radio Toilet paper 1 roll per 5 people Fuel (unleaded) 5 gallons = 20 hours chainsaw use Bar oil 10 quarts = 20 hours chainsaw use 2 cycle mix 12.8 ounces = 20 hours chainsaw use Fuel (24:1) Mark III: 5 gallons = 3 hours Shindaiwa: 5 gallons = 10 hours
Page 17
NWCG Guide for Wildland Fire Modules 14 of 76 Longline Remote Hook Setup
Page 18
NWCG Guide for Wildland Fire Modules 15 of 76 Radios KNG-P150S Portable Radio
Page 19
NWCG Guide for Wildland Fire Modules 16 of 76 BKR 5000 Portable Radio
Page 20
NWCG Guide for Wildland Fire Modules 17 of 76 Individual KNG-P150S and BKR 5000 radios may be set up differently by local technicians. This information is provided only as a general guide to the use and functionality of the KNG-P150S and BKR 5000. Scan and Priority Scan Scan • Used to add and delete channels in the scan list and scan channels within the selected zone. • Within the desired zone, press the [MENU] button (diamond button). • Scroll down to “Scan List” using the triangle buttons and press [ENT] (square button). This will bring you to the Channel Scan page. • Press [+/-] (square button) on the display and a + will appear next to the channel. Press [+/-] again to remove a channel from the scan list. • Continue adding until all desired channels are selected. • Press [ESC] (diamond button) to return to the home screen. • While using the channel select knob to scroll through channels, you will see “SCN” appear on the upper part of the display on all channels you selected to scan. • Toggle the [SCAN] switch forward and back to turn scanning on and off. “SCN” will flash when the currently selected channel is being scanned. • If a scanned channel becomes unneeded or annoying, the nuisance delete button (if programmed in your radio) can temporarily disable that channel while you are receiving a transmission on it. This will stop the scanning of a channel without deleting it from the scan list. Turn off scan for at least five seconds or cycle radio power to resume normal functionality. Priority Scan • Used to add a priority scan channel that will have priority over your other scanned channels and the currently selected channel. When priority scan is activated, you will automatically talk on that channel if the “TX on Priority 1” setting is activated. • The radio may be programmed with a [PRI] button to allow you to easily change your priority channels. If not, you can access priority settings through “Zone Params” under the keypad programming option. • In the “Pri Chans” menu, use the triangle buttons to scroll to “Priority 1” and press [ENT]. • Scroll to “Use Per Zone” and press [ENT]. • Use the triangle buttons to scroll to your desired priority channel and press [ENT]. You can also turn priority channels off or use the “Main” setting for your priority channel to be set to whatever channel the select knob is currently turned to. • Press [ESC] until you are back to the home screen. • Using the channel select knob, scroll to the channel you selected as priority. You should see a P1 in the upper left part of the display on the home screen. • Using the channel select knob, scroll to another channel.
Page 21
NWCG Guide for Wildland Fire Modules 18 of 76 • Toggle the [PRI] switch forward and back to turn your priority channel on and off. • The “Priority 2” setting can be activated using the same method, allowing you to select a secondary priority channel. This channel will take priority over all other channels except the selected priority 1 channel when receiving transmissions. Scan and Priority Scan Together • When both the [SCAN] and [PRI] switches are toggled forward, both the scan list and priority channel list will be active and there will be indicators on the upper part of the display. Squelch • Used for a channel without a tone on the receiver to control how weak of a signal your radio will pick up. If there is a tone on the receiver and you are receiving poorly or not at all, the squelch setting will not be helpful. • If your radio is programmed with this functionality, press the [SQL] button on the home screen. • This will bring you into the “Squelch Set” menu. • Using the triangle button, scroll to “User Set” and press [ENT]. • Using the triangle buttons, scroll up, or down to adjust your squelch to the desired level. The up- arrow button will open squelch to allow more static noise or weaker RF signals to be heard from the speaker. The down-arrow button will close squelch, requiring the radio to receive a stronger RF signal to be heard at the speaker. • When finished, press [ENT] to be automatically returned to the home screen. User TX Tones (Transmit Tone Select) • Used to select from preprogrammed tones to manually choose a code guard. • If your radio is programmed with this functionality, press the [TCG] button on the home screen. • This will bring you into the “User TX Tones” menu. • Using the number pad, type in the tone you would like to select or use the triangle buttons to scroll to a desired tone. • Press [ENT] to choose your desired tone and be automatically returned to the home screen. • The [TCG] marker should now be highlighted, indicating that a code guard has been selected. • User RX tones (receive code guards) can be selected in an identical fashion by entering the “User RX Tones” option while in the [MENU] settings. Keypad Programming • Press the [MENU] button. • Using the triangle buttons, scroll to “Keypad Prog” and press [ENT]. • Press [ENT] again on the “Keypad Prog” submenu. • Enter the password. Default is 000000 (six zeros). Press [ENT]. • This will allow you to select from three menus (“Channels,” “Zone Params,” and “Global
Page 22
NWCG Guide for Wildland Fire Modules 19 of 76 Params”), explained in further detail below. Channels • The bulk of programming options are located here. • Select a zone to hand program from the “Select Zone” menu. • Select a channel within that zone from the “Select Chan” menu and choose from the following options: o Chan Label: Used to edit a channel label. Press [CLR] to clear text. Use the numbers on the number pad to enter text according to the letters printed on the buttons. The “0” key will insert a blank space, while the “#” key will scroll through special characters. o RX Freq: Changes the receive frequency. Press [CLR] to clear text. Enter a new frequency using the number pad and press [ENT]. o RX Mode: Choose between analog and digital mode for receiving transmissions. Should be listed on any fire communications plan, but default to “analog” if you are unsure. Press [ENT] to choose. o RX Guard: Changes the tone guard for receive frequencies. Press [CLR] to clear text. Enter a new tone guard using the number pad and press [ENT]. o RX NAC: Only applicable when in digital mode. This setting is the digital equivalent of a tone guard. o Squelch Mode: Only applicable when in digital mode. Used to manipulate how strong or weak of a signal your radio will pick up. o TX Freq: Changes the transmit frequency. Press [CLR] to clear text. Enter a new frequency using the number pad and press [ENT]. o TX Mode: Choose between analog and digital mode for sending transmissions. Should be listed on any fire communications plan, but default to “analog” if you’re unsure. Press [ENT] to choose. o Bandwidth: Choose between narrowband (12.5 kHz) and wideband (25 kHz). Modern frequencies will generally be narrowband. Press [ENT] to choose. o TX Guard: Changes the tone guard for transmit frequencies. Press [CLR] to clear text. Enter a new tone guard using the number pad and press [ENT]. o TX NAC: Only applicable when in digital mode. This setting is the digital equivalent of a tone guard. o TGID: Talkgroup ID. Only applicable to digital mode. o Secure Mode: Choose between clear and secure. Secure mode is only used for encryption. Default to clear mode. o Key: Refers to encryption keys. Only applicable to digital mode and encryption. o Key Lock: Encryption key functionality. Default to off. o Low Power Lock: Locks the channel in low power mode. High power mode will be unavailable. Press [ENT] to select on or off. o Plist Disable: Turns on or off the ability to select code guards from a picklist. Default to off.
Page 23
NWCG Guide for Wildland Fire Modules 20 of 76 Press [ENT] to make your selection. • Press [ESC] to return to the “Select Chan” menu. Scroll to the next channel using the triangle buttons and press [ENT] to select. Repeat the steps above to program another channel. Zone Parameters • Used to select from options that apply to specific zones. Choose from the following options: o Zone Label: Used to edit a channel label. Press [CLR] to clear text. Use the numbers on the number pad to enter text according to the letters printed on the buttons. The “0” key will insert a blank space, while the “#” key will scroll through special characters. o Pri 1 Chan: Select a priority channel (discussed above in the “Priority Scan” section). o TX on Pri 1: Controls whether your radio will default to transmitting on the currently set priority 1 channel even while the channel select knob is turned to a different channel. Useful for quickly toggling between two channels of interest – set your priority channel to the most important, and use the channel select knob to choose a secondary channel. Toggling the [PRI] switch will now rapidly switch between transmitting on two channels. Press [ENT] to choose between on and off. o Pri 2 Chan: Select a secondary priority channel, as discussed above in the “Priority Scan” section. o ANI mode: Used to select DTMF tone options. Infrequently used, but useful for obtaining information from Remote Automatic Weather Stations (RAWS) stations. o ANI ID: Associated with the ANI mode settings and transmission of DTMF tones. o Disable Clone: Disables the ability to clone over this zone. o Disable Plist: Disables picklists. Default to off. o Ignore Plist: Ignore option for picklists. Default to off. o Enable UCG: Enables the ability to manually select code guards from a preprogrammed list. Default to on. o UCG TX Only: Selecting code guards will only apply to transmissions if this setting is enabled. Choose from on or off and press [ENT]. o UCG NAC Only: Digital equivalent of tone guard settings. Global Parameters • Used to select from options that apply to all zones on the radio. Choose from the following options: o Pri 1 Chan: See above on selecting a priority channel. The difference here is the chosen channel will apply to all zones. Potentially useful if you need to listen to a channel not programmed into your current zone. o Pri 1 Zone: Choose the zone for your global priority channel. o Pri 2 Chan: As above for priority 2 channel. o Pri 2 Zone: As above for priority 2 zone.
Page 24
NWCG Guide for Wildland Fire Modules 21 of 76 o SCN Hold Time: Controls the amount of time a radio will continue looking for new transmissions on a specific channel after a transmission has been received. o Busy Ch Mode: Controls indicator lights for whether a channel is receiving a transmission. o TX TOT: Sets a timeout for all transmissions. Potentially useful to avoid a hot mic situation. o Bklight Mode: Controls how the backlight on the radio behaves. Choose from “Off” (always off), “Keypress” (display lights up on button press), “Display Chn” (display lights up when any new information is received), or “Both.” o Bklight Dur: Controls how long the backlight will light up for. Choose from 1-6 seconds or always off/on. o Volume Tone: Controls whether sound is played when volume is changed. Default to off. o Password: Change the password required to enter keypad programming mode. o P25 Unit ID: Used for P25 digital radio functions (infrequently used). o TX Max Power: Choose between “Medium” and “High” to alter the power used to send transmissions while in high power mode. o TX Low Power: Choose between “1 Watt” and “2 Watts” to alter the power used to send transmissions while in low power mode. o Pri SCN HTime: Affects frequency of scanning for priority channel transmissions. Giving a Clone 1. Using an appropriate cloning cable, attach the master radio to a compatible radio. Cloning works best with identical radios but can be used with care across Bendix King models. 2. From the home screen, press [MENU] and scroll to “Cloning” and choose from the following options: a. Active Zone: Copies the currently selected zone from the master radio and programs it into the currently selected zone on the target radio. b. Zone-to-Zone: Allows you to select a specific zone on the master radio to clone to the currently selected zone on the target radio. c. Entire Radio: Allows you to clone all zones on the master radio to the target radio. 3. After selection, the radio will ask if you would like to clone UCG/PL. Default to no unless you need specific code guard functionality. 4. The clone will start and inform you on success or failure. 5. Repeat steps 1-4 for the next radio. Receiving a Clone • Select the zone you would like to receive the clone on, attach cloning cable to the radio and wait for the clone.
Page 25
NWCG Guide for Wildland Fire Modules 22 of 76 Bendix King DPHX (Legacy) Portable Radio
Page 26
NWCG Guide for Wildland Fire Modules 23 of 76 Programming 1. Using a programming plug, hold the red plug button and the [FCN] key until the display shows “-- -- -- ID.” • Older truck radios will be programmed similarly. Press and hold the [HOM/SQL] key on the main unit while holding the [FCN] key on the mic to enter programming mode. 2. Enter the password (default: 000000), then press the [ENT] key. 3. Display will read “CH 00”. Select a channel by entering the associated number (1-16), then press the [FCN] key. 4. Display will show “RX” (receive frequency). To change, press [CLR], then enter desired frequency (decimal will be automatically inserted) and press [ENT]. 5. Display will show “MODE--A”. Do not change. Press [FCN] to skip. 6. Display will show “RX CG”, representing the code guard or tone. To change, press [CLR], enter in desired 4 digits (decimal will be automatically inserted), then press [ENT]. To skip, press [FCN]. 7. Display will show “NAC0000”. Do not change. Press [FCN] to skip. 8. Display will show “SQL—NRM ”. Do not change. Press [FCN] to skip. 9. Display will show “TX” (transmit frequency). To change, press [CLR], then enter desired frequency (decimal will be automatically inserted) and press [ENT]. 10. Display will show “MODE--A” Do not change. Press [FCN] to skip. 11. Display will show “TX CG”, representing the code guard or tone. To change, press [CLR] and enter in desired 4 digits (decimal will be automatically inserted), then press [ENT]. To skip, press [FCN]. 12. Display will show “NAC0000”. Do not change. Press [FCN] to skip. 13. Display will show “TG00001”. Do not change. Press [FCN] to skip. 14. Display will show channel label. See the next section for label editing instructions. To skip, press [FCN]. 15. Display will read “CH XX”. Press [PRI] to select next channel to program. Repeat steps 1-14. Editing Channel and Group Labels • To enter a new label, press the [FCN] key. The display will become blank. • Press the [PRI] key repeatedly to cycle through characters 0-9, A-Z, -, *, $, /, +, %, \, _, <, >, h, blank, then back to the start again. The characters appear in position eight. If you pass the desired character, press the [PRI] key repeatedly until you reach that character again. • Press the [FCN] key to shift the display left by one position, leaving position eight blank. • Press the [PRI] key repeatedly to enter the next character or press the [FCN] key a second time to enter a blank space. • Press number keys to enter 0-9 in positions one through seven. The digits start in position seven, then move left.
Page 27
NWCG Guide for Wildland Fire Modules 24 of 76 • Press the [#] key to toggle a decimal on or off to the right of the character in position seven. The decimal moves left with the number in position seven as new numbers are entered. • To abandon changes, press the [CLR] key, restoring the original label. • Press the [ENT] key to store changes and go back to the starting point. Cloning 1. Obtain programmed master radio. 2. Turn on master radio and radio to be programmed and attach cloning cable. Ensure all scan and priority toggles are OFF on both radios. 3. Select desired group to clone over on radio to be programmed. 4. Access the programming mode of the master radio (see the programming section above). 5. With the master radio display reading “CH 00”, press the * key on the master radio. 6. “PRGM” will appear flashing on the screen. 7. Press the Function [FCN] key and “PRGM” will stop flashing as the second radio is programmed. The screen on the second radio will flash “VH-1”. 8. Turn off the second radio and connect and program the next radio by pressing the [FCN] key again. 9. If display reads “FAIL”, an error has occurred. Turn off both radios and repeat steps 2-8. If “FAIL” appears again, seek help. Other Notes • If you want to change a frequency from narrowband to wide: o When in programming mode, after entering a channel number you may see an N after the number – for example, 15N. The N means the frequency is narrowband. o Press the [#] key. The N should disappear, and the channel will be in wideband mode. • If you have trouble keying in a tone or changing groups, your keypad may be locked. If the screen says “LOCKED”, press and hold the [FCN] key until it reads “UNLOCKED”. Zero Codes The zero codes control numerous features of the Bendix King (BK) radio. Use caution when changing. • Follow programming steps 1-2 above. Press the [FCN] key 7 times to arrive at zero code group 1, 8 times for group 2, and 9 times for group 3. • Zero codes are specific to each individual group. • A function is enabled in the radio if the associated number is flashing. For example, to enable DTMF encoder, the number 5 must be flashing in the Group 2 functions. In the chart, you’ll see that the number 5 is grey next to the “Manual DTMF Encoder” setting. • To change a number from flashing to solid (disable a function), simply touch the number on the keypad, then press [ENT]. The opposite will also work: to change a number from solid to flashing (enable a function), touch the number on the keypad, then press [ENT].
Page 28
NWCG Guide for Wildland Fire Modules 25 of 76 • In the following table, a function is enabled if a particular number is grey. • For a more detailed explanation of the functions, see the information on the page following the table. Group One Functions Battery Saver Off 1 1 2 3 4 5 Group Scan List 1 1 2 3 4 5 Transmit on Priority 1 1 1 2 3 4 5 Priority Key Lockout 1 1 2 3 4 5 Scan List Lockout 1 1 2 3 4 5 Group Two Functions User Code Guard 2 1 2 3 4 5 Busy Channel Indicator 2 1 2 3 4 5 Busy Channel Lockout 2 1 2 3 4 5 Busy Channel Override 2 1 2 3 4 5 ANI 2 1 2 3 4 5 Manual DTMF Encoder 2 1 2 3 4 5 Group Three Functions Light on Display Change 3 1 2 3 4 5 Light on Key Press 3 1 2 3 4 5 Alphanumeric Mode 3 1 2 3 4 5 National Standard Tones/NACs Tone # Analog Freq DEC NAC HEX NAC 1 110.9 1109 455 2 123.0 1230 4CE 3 131.8 1318 526 4 136.5 1365 555 5 146.2 1462 5B6 6 156.7 1567 61F 7 167.9 1679 68F 8 103.5 1035 40B 9 100.0 1000 3E8 10 107.2 1072 430 11 114.8 1148 47C 12 127.3 1273 4F9 13 141.3 1413 585 14 151.4 1514 5EA 15 162.2 1622 656 16 192.8 1928 788
Page 29
NWCG Guide for Wildland Fire Modules 26 of 76 Zero Code Function Explanations • Battery Saver Off: When enabled, disables the battery saver function. • Group Scan List: When enabled, current group will be scanned if in group scan mode. • Transmit on Priority 1: When enabled, radio will transmit on priority 1 channel rather than currently selected channel if priority scan is toggled on. • Priority Key Lockout: When enabled, [PRI] key will be locked out on radio, disabling the user’s ability to change the priority 1 channel. • Scan List Lockout: When enabled, user will not be able to add/remove channels from the scan list. • User Code Guard: When enabled, allows user to manually select code guard value while transmitting. • Busy Channel Indicator: When enabled, yellow LED will illuminate when signal is received on selected channel. • Busy Channel Lockout: When enabled, push-to-talk is disabled when a signal is active on selected channel. • Busy Channel Override: When enabled, push-to-talk is disabled but can activate squelch code guard. • ANI: When enabled, programmed ANI ID number will be transmitted on push-to-talk as a DTMF tone. • Manual DTMF Encoder: When enabled, DTMF tones can be transmitted with the keypad. • Light on Display Change: When enabled, LCD backlight will illuminate each time the display receives an input. • Light on Key Press: When enabled, LCD backlight will illuminate each time a key is pressed. • Alphanumeric Mode: When enabled, LCD will display alphanumeric characters.
Page 30
NWCG Guide for Wildland Fire Modules 27 of 76 Mapping Township/Range/Section System of Land Measure • Township lines run EAST to WEST six miles apart. Range lines run NORTH to SOUTH six miles apart. • Within each township are 36 sections, each one-mile square. Each section contains 640 acres. Section numbers in a typical township. 6 5 4 3 2 1 7 8 9 10 11 12 18 17 16 15 14 13 19 20 21 22 23 24 30 29 28 27 26 25 31 32 33 34 35 36 • Within each section, the land is referred to as half and quarter sections. A one-sixteenth division is called a quarter of a quarter, as in the NW 1/4 of the NW 1/4. • The descriptions are read from the smallest division to the largest. Various segments and their descriptions Line names in the township/range/section system
Page 31
NWCG Guide for Wildland Fire Modules 28 of 76 Converting Latitude/Longitude • The easiest way to convert GPS coordinates is with a mobile app (Avenza, Gaia, etc.). • Avenza Maps – in the map view, tap the coordinates displayed at the bottom center of the screen. All possible coordinate systems will be shown, allowing for easy conversion. • Gaia Maps – Menu > Settings > Coordinate Type. • If you do not have a mobile app available: o Latitude and Longitude may be shown in three different formats: Format Visual Radio Etiquette Degrees Decimal Minutes 48° 36.12’, 114° 08.12’ “Four-eight degrees, three six point one two minutes.” Degrees Minutes Seconds 48° 36’ 12”, 114° 08’ 12” “Four-eight degrees, three six minutes, one two seconds.” Degrees Decimal Degree 48.3612°, 114.0812° “Four-eight point three six one two degrees.” • To convert Degrees Minutes Seconds to Degrees Decimal Minutes, divide seconds by 60. o Example: 48° 20’ 30” (30”)/60 =.5’ 48° 20.5’. • To convert Degrees Decimal Minutes to Degrees Minutes Seconds, multiply hundredths by 60. o Example: 48° 20.5’ .5’ x 60 = 30” 48° 20’ 30”. • One degree of latitude or longitude = 60 minutes (60’). • One minute of latitude or longitude = 60 seconds (60”). • A 7.5-minute quad covers 7.5 minutes of longitude and 7.5 minutes of latitude. • For aviation purposes: o Datum = WGS84. o Units = Degrees Decimal Minutes. • Degrees Decimal Minutes are a safe default and can be converted to any other desired format.
Page 32
NWCG Guide for Wildland Fire Modules 29 of 76 Area and Distance Conversion Charts Units of Measure 1 inch 2.54 cm 1 foot 0.3048 meters 1 meter 39.37 inch 3.28 feet 1 kilometer 3280.8 feet 1093.6 yards 0.623 miles 1 mile 5280 feet 80 chains 1.6 kilometers 1 chain 66 feet 20.11 meters 1 acre 43560 sq ft 10 sq chains .405 hectares 1 section 640 acres 1 sq miles 1 range 5760 acres 9 sq miles 1 township 23040 acres 36 sq miles Map Scale Conversion Map Scale Earth Measure per Map Inch Inches on Map per Earth Mile 1:5000 416.67 feet 127 meters 12.67 1:10000 833.3 feet 254 meters 6.34 1:12500 1041.7 feet 317 meters 5.07 1:20000 1666.7 feet 508 meters 3.17 1:24000 (7.5” quad) 2000 feet 609.6 meters 2.64 1:25000 (7.5” quad) 2083.3 feet 635 meters 2.53 1:50000 4166.7 feet 1270 meters 1.27 1:62500 (15” quad) 5206.1 feet 1586.8 meters 1.01 1:63360 (Alaska maps) 5280 feet 1609.3 meters 1.00 1:100000 8333.3 feet 2540 meters 0.63 1:250000 20833 feet 6350 meters 0.25 1:500000 41667 feet 12700 meters 0.13
Page 33
NWCG Guide for Wildland Fire Modules 30 of 76 Declination Map
Page 34
NWCG Guide for Wildland Fire Modules 31 of 77 Avenza and Mobile Mapping Guide Recording Waypoints and Tracks • There are several mobile apps that can easily record points and tracks and share them via AirDrop (iPhone), Bluetooth (Android), or email. The following apps have largely replaced separate GPS units for WFM crewmembers: • Avenza Maps: Commonly used GPS app with downloadable base maps. • Gaia GPS: Alternative GPS app with different base layers available. • ArcGIS Field Maps: Used by Incident Management Teams (IMTs) for Field Observers (FOBS) such as data collection on large incidents. Find field guide here: https://ftp.wildfire.gov/public/incident_specific_data/Fuels/AZ_TNF/General/Documents/Field%20 Maps%20Guide%20iOS.pdf. • Acquiring Maps (Avenza Specific): o Enter the “Store” tab. o Use the search function to download topographical, park and forest, and other maps. o It is possible to filter for “free maps only” in the Avenza store. o If the relevant incident has a QR code for maps, click the QR symbol at the top right. o For large incidents, download the latest maps from https://ftp.wildfire.gov/public/incident_specific_data/. o Alternatively, you can find topographical maps from sources like USGS TopoView, download them onto your device, and import directly into Avenza. Sharing Maps With AirDrop (iPhone Only) • Open the desired map and click on the map layer symbol at the bottom right. • Click on the symbol at the bottom right to export. • Using a straightforward file name, send to “Airdrop,” select “Custom” data and make sure you’ve checked the box next to the map. Tap “Apply.” • Tap “Export,” make sure your AirDrop is turned on, and wait for your target’s phone to appear on the list. • The same process is used for sharing points and tracks. Recording Tracks and Calculating Acreage • Avenza: o While in the map view where your perimeter will go, click on the icon in the bottom right. o Tap “Record GPS Tracks,” then tap “Start Tracking.” Walk the perimeter. Tap “Stop Tracking” when you’ve finished the track or completed the perimeter. o This is the track you will send to whomever needs it. To find the area, tap on the track to enter the “Edit Track” dialogue. Tap “Convert to Area” to transform your track into a polygon showing the area of your unit. Tap on the area that was just created to enter the “Edit Area” dialogue, and tap “Details” to change the units shown for perimeter distance and area (allowing you to obtain the area in acres, square feet, etc. without performing any manual conversions). • Gaia: o Simply record a track, and when you’ve completed the track, click “convert to area.”
Page 35
NWCG Guide for Wildland Fire Modules 32 of 77 Weather and Fire Behavior Cloud Types
Page 36
NWCG Guide for Wildland Fire Modules 33 of 77
Page 37
NWCG Guide for Wildland Fire Modules 34 of 77 Wind Adjustments for Exposure of Fuels to Wind The following wind adjustments can be used to translate between forecasted 20-foot winds and winds experienced at eye level. Visual representation of different fuel exposure models Fuel Exposure Fuel Model Adjustment Factor Exposed Fuels Fuel exposed directly to wind, no, or sparse overstory. Fuel beneath timber that has lost foliage overstory or is near clearings or clear-cuts. Fuel on high ridges where trees offer little shelter from the wind. 4 0.6 13 0.5 All others 0.4 Partially Sheltered Fuels Fuel beneath patchy timber not well sheltered. Fuel beneath standing timber at mid-slope or higher on a mountain with wind blowing directly at the slope. All fuel models 0.3 Fully Sheltered Fuels Fuel sheltered beneath standing timber on flat or gentle slope or near base of mountain with steep slope. All models (open stands) 0.2 All models (dense stands) 0.1
Page 38
NWCG Guide for Wildland Fire Modules 35 of 77 Rate of Spread Estimation Use the following directions for estimating rate of spread: • Measure out 1, 3, 5, or 10 feet between two points in an area the fire is spreading toward. • Record the time it takes for fire to spread between these two points. • Using the appropriate spread distance column (1, 3, 5, or 10 feet), find the two values the recorded spread time falls between. • The rate of spread in chains per hour is between the two corresponding numbers in the rightmost column. Example: Suppose you are monitoring a backing fire burning in light ponderosa needle cast. Measure out 3 feet, and place two stones at each of the points. Time the fire as it moves between the stones. In this case, suppose the fire takes 1 minute and 6 seconds (1’6”) to move 3 feet. Looking at the 3 feet column, move down until reaching two times which bracket this time: 1’22” and 55”. The corresponding numbers in the rightmost column give us the rate of spread: between 2 and 3 chains per hour. Flame measurements diagram Spread Distance (feet) 1 3 5 10 Time in Minutes (‘) and Seconds (“) Rate Of Spread (Chains /ho ur) 3’38” 10’55” 18’10” 36’22” 0.25 1’49” 5’27” 9’05” 18’10” 0.50 55” 2’44” 4’33” 9’05” 1 36” 1’49” 3’02” 6’04” 1.50 27” 1’22” 2’16” 4’33” 2 18” 55” 1’31” 3’02” 3 14” 41” 1’08” 2’16” 4 11” 33” 55” 1’49” 5 9” 27” 45” 1’31” 6 8” 23” 39” 1’18” 7 7” 20” 34” 1’08” 8 6” 18” 30” 1’01” 9 5” 16” 27” 55” 10 4” 11” 18” 36” 15 3” 8” 14” 27” 20 2” 7” 11” 22” 25 2” 5” 9” 18” 30 2” 5” 8” 16” 35 1” 4” 7” 14” 40 1” 3” 5” 11” 50
Page 39
NWCG Guide for Wildland Fire Modules 36 of 77 Sling Psychrometer Use The following are instructions for determining wet and dry bulb temperatures using the sling psychrometer: 1. Stand in a shaded, open area away from objects that might be struck during whirling. If in open country, use your body to shade the psychrometer. If possible, take weather observations over a fuel bed that is representative of the fuels that the fire is burning in. 2. If your sling has been in your pack, you may need to hang it in a tree in the shade to allow it to adjust to the outside air temperature. 3. Face the wind to avoid the influence of body heat and moisture on the thermometers. 4. Saturate the wick of the wet bulb with clean, mineral free water (distilled). Never touch the wick. 5. Ventilate the thermometers by whirling at full arm’s length. Your arm should be parallel to the ground. Whirl for 1 minute. 6. Note the wet bulb temperature. Whirl another 40-50 times and note the wet bulb temperature again. If the second reading is lower than the first, continue to whirl, and read until it will go no lower. Record the lowest point. If the wet bulb is not read at the lowest point, the calculated relative humidity will be too high. 7. Read the dry bulb immediately after the lowest wet bulb reading is obtained. If the wet bulb reading increases, the wick has dried out. Wet the wick and begin again. 8. Determine the relative humidity and dew point using the tables provided. Tips: • Never sling weather in the black. • Ensure a quality sling (clean wick, non-separated mercury/liquid, clean water, etc.). • Always use the correct elevation chart for relative humidity and dew point. • As a rule of thumb, divide relative humidity by 5 to obtain an estimate of fine dead fuel moisture.
Page 40
NWCG Guide for Wildland Fire Modules 37 of 77 Fuel Moisture Sampling General Guidelines • Record site name, date, time, observer name, observed weather, and general site description. • Do not collect samples if water drops or dew are present on samples. • Keep samples in a cool and dry location. • Seal containers with tape that will not leave residue. Electrical tape works well. Dead Fuels (1-hour, 10-hour, 100-hour, and 1000-hour) • Samples should not be attached to live trees or shrubs. • Avoid decayed samples that crumble or splinter when rubbed. • Collect samples from several different plants. • Ensure container is ¾ full to avoid overfilling/spilling between measurements. • Do not collect buried samples. • Pick samples of different size within the timelag class. • Recently fallen material should be avoided, especially for the larger size classes. • Remove all lichen, moss, and very loose bark from sample. • 1000-hour fuels should be collected at least 1 foot from the end of the downed log, and should ideally be cut with a handsaw, rather than a chainsaw. Storage of the “cookie” should be in an airtight container and “wet” weight should be read as soon as possible. An auger/drill can also be used to collect 1000-hour woodchips, which can be stored in a standard fuel tin. Duff and Soil • Remove all soil and live tree or plant roots from sample. • Avoid any soil particles in duff samples and vice versa. Litter • Collect only un-compacted dry litter from both sunny and shady areas. Live Fuels (Live Woody Shrub Leaves and Tree Needles/Leaves) • Only collect foliage and very small twigs and remove flowers, seeds, nuts, and berries. • Pack containers loosely to avoid spillage, but ensure container is ¾ full. • Include stems of herbaceous plants. • Replace lid on container immediately after collecting sample and seal with electrical tape. Drying Samples • Preheat drying oven between 60°C (140°F) and 100°C (212°F). Be sure to note temperature used.
Page 41
NWCG Guide for Wildland Fire Modules 38 of 77 • Place sample cans with closed lids on scale and record “wet” weights (be sure to remove tape first). • Remove lid just prior to placing in oven. If material is lost, re-weigh sample. • Dry sample for 24 hours (very wet samples may require 48 hours). • Replace lids immediately after sample is removed from oven and weigh. • Calculate fuel moisture using the following formula: 𝑤𝑤𝑤𝑤𝑤𝑤 𝑤𝑤𝑤𝑤𝑤𝑤𝑤𝑤ℎ𝑤𝑤 𝑜𝑜𝑜𝑜 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑤𝑤− 𝑑𝑑𝑑𝑑𝑑𝑑 𝑤𝑤𝑤𝑤𝑤𝑤𝑤𝑤 ℎ𝑤𝑤 𝑜𝑜𝑜𝑜 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑤𝑤 𝑑𝑑𝑑𝑑𝑑𝑑 𝑤𝑤𝑤𝑤𝑤𝑤𝑤𝑤 ℎ𝑤𝑤 𝑜𝑜𝑜𝑜 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑤𝑤− 𝑐𝑐𝑜𝑜𝑐𝑐𝑤𝑤𝑠𝑠𝑤𝑤𝑐𝑐𝑤𝑤𝑑𝑑 𝑤𝑤𝑤𝑤𝑤𝑤𝑤𝑤ℎ𝑤𝑤∗ 100 = % 𝑠𝑠𝑜𝑜𝑤𝑤𝑠𝑠𝑤𝑤𝑚𝑚𝑑𝑑𝑤𝑤 𝑐𝑐𝑜𝑜𝑐𝑐𝑤𝑤𝑤𝑤𝑐𝑐𝑤𝑤 Fuel Moisture Calculation Table A B Gross Weight Wet Dry C D E F C ontainer Tare Weight Water Weight Dry Weight % Moisture Content Calculation Summary: A (wet weight of sample) – B (dry weight of sample) = D (water weight) B (dry weight of sample) – C (container weight) = E (dry weight) D (water weight) / E (dry weight) * 100 = F (% moisture content) Fuel Size Classes – Woody Debris Dead Woody Class Piece Diameter inches centimeters 1 hour 0-0.25 0-0.6 10 hours 0.25-1.0 0.6-2.5 100 hours 1.0-3.0 2.5-8.0 1000 hours and greater 3.0 and greater 8.0 and greater
Page 42
NWCG Guide for Wildland Fire Modules 39 of 77 Live Fuel Moisture Estimates If data are unavailable for live fuel moisture content (required for fuel models 2, 4, 5, 7, and 10), the following rough estimates can be used instead. Stage of Vegetative Development Moisture Content Fresh foliage, annuals developing, early in growing cycle. 300% Maturing foliage, still developing with full turgor. 200% Mature foliage, new growth complete, and comparable to older perennial foliage. 100% Entering dormancy, coloration starting, some leaves may have dropped from stem. 50% Completely cured. less than 30% (treat as dead fuel)
Page 43
NWCG Guide for Wildland Fire Modules 40 of 77 Fuel Models Anderson 1982 – “The Original 13” Primary carrier of the fire is GRASS • FM1 – Grass is finely structured, generally below knee level, primarily cured, and essentially continuous. Spread rate moderate, flame length low. Grasslands, savanna, grass tundra. • FM2 – Grass is usually under an open timber or brush overstory. Litter from the overstory is partially involved in carrying fire, but grass is the primary carrier of the fire. Expected rate of spread is less than FM1 and intensity is less than FM3. Spread rate moderate, flame length moderate. Open shrub land and pine stands, some pinon-juniper. • FM3 – Grass is coarse structured, above knee level (average about 3 feet deep) and can be difficult to walk through. 1/3 of stand is dead or cured. Spread rate high, flame length high. Primary carrier of the fire is BRUSH or LITTER beneath the BRUSH • FM4 – Brush is head height (over 6 feet), with heavy loadings of dead woody fuel. Fire may involve foliage, live and dead woody material, and canopy. Spread rate very high, flame length very high. Mixed chapparal, high pocosin, pine barrens of New Jersey, closed jack pine stands of north central states. • FM5 – Brush is about 2 feet high, with light loading of brush litter underneath. Litter may carry fire, especially at low wind speeds. Young green stands with little or no deadwood. Spread rate low to moderate, flame length low to moderate. Laurel, vine maple, alder, manzanita. • FM6 – Live fuels are absent or sparse. Brush averages 2 to 4 feet high. Brush requires moderate winds to carry fire. May not predict rate of spread accurately in mature pinyon-juniper or taller oak brush. Spread rate high (with wind), flame length high. Chapparal, chamise, oak brush, low pocosin, Alaskan black spruce, taiga, shrub tundra, pinyon-juniper at high winds (20mph at 20’ level). • FM7 – Fires burn through the surface and shrub strata with equal ease and can occur at higher dead fuel moisture contents due to the flammability of live foliage and other live material. Stands of shrubs are generally between 2 and 6 feet high. Spread rate high, flame length high. Palmetto- gallberry understory with pine overstory, Alaskan black spruce with shrub. Primary carrier of the fire is LITTER beneath a TIMBER stand • FM8 – Dead foliage is tightly compacted, short needle (2 inches or less) conifer or hardwood litter. Spread rate low, flame length low (with occasional jackpots of heavy fuels increasing intensity). White and lodgepole pine, spruce, true firs, larches. • FM9 – Dead foliage litter is loosely compacted long-needle pine or hardwoods. Concentrations of dead and down woody material will contribute to possible torching of trees, spotting, and crowning. Spread rate moderate, flame length moderate. Closed stands of long-needle pine – Jeffrey ponderosa, southern pine plantations.
Page 44
NWCG Guide for Wildland Fire Modules 41 of 77 • FM10 – There is a significant quantity of larger fuels with attached branches and twigs, or fuels that have rotted enough to be splintered and broken. The larger fuels are reasonably well distributed over the area. Some green fuel may be present. Overall depth of the fuel is primarily below knee level, but some fuel may be higher. Any forest type may qualify if heavy down material is present. Crowning, spotting, and torching of individual trees are more frequent in this fuel model, leading to potential fire control difficulties. Spread rate moderate to high, flame length high. Insect- or disease-ridden stands, windthrown stands, overmature situations with deadfall, and aged light thinning or partial-cut slash. Primary carrier of the fire is LOGGING SLASH • FM11 – Slash is not continuous. Needle litter or small amounts of grass or shrubs must be present to carry the fire, but primary carrier is still slash. Live fuels are absent or do not play a significant role in fire behavior. Spread rate low, flame length moderate. Light partial cuts or thinning operations in mixed conifer or hardwood stands and southern pine harvests. • FM12 – Slash generally covers the ground, with heavier loadings than FM11, though there may be some bare spots or areas of light coverage. Average slash depth is about 2 feet. Slash is not excessively compacted. Approximately ½ of the needles may still be on the branches but are not red. Live fuels are absent or not expected to affect fire behavior. Spread rate low, flame length moderate to high. Heavily thinned conifer stands, clear-cuts, and medium to heavy partial cuts. • FM13 – Slash is continuous or nearly so, with heavier loadings than FM12. Slash is not extremely compacted and has an average depth of 3 feet. Approximately ½ of the needles are still present and are red, or all the needles are still on the branches but are green. Live fuels are not expected to influence fire behavior. Spread rate low, flame length high. Clear-cuts and heavy partial cuts in mature or over mature stands where slash is dominated by greater than 3-inch diameter materials or load like FM12 but with “red” needles still attached.
Page 45
NWCG Guide for Wildland Fire Modules 42 of 77 Scott and Burgan 2005 – “The New 40” • Determine the general fire-carrying fuel type (grass, grass/shrub, shrub, timber/understory, timber litter, slash, or non-burnable). • Determine general climate in the area (arid, semiarid, subhumid, humid). Timber litter fuel models do not have climate groupings. • Match a fuel model description (depth, load, continuity) with the fuels of interest. Nearly pure grass and/or forb type (grass): Arid to semiarid climate (rainfall deficient in summer). Extinction moisture content is 15%. • GR1 – Grass is short, patchy, and possibly heavily grazed. Spread rate moderate, flame length low. • GR2 – Moderately coarse continuous grass, average depth about 1 foot. Spread rate high, flame length moderate. • GR4 – Moderately coarse continuous grass, average depth about 2 feet. Spread rate very high, flame length high. • GR7 – Moderately coarse continuous grass, average depth about 3 feet. Spread rate very high, flame length very high. Subhumid to humid climate (rainfall adequate in all seasons). Extinction moisture content is 30-40 %. • GR1 – Grass is short, patchy, and possibly heavily grazed. Spread rate moderate, flame length low. • GR3 – Very coarse grass, average depth about 2 feet. Spread rate high, flame length moderate. • GR5 – Dense coarse grass, average depth about 1-2 feet. Spread rate very high, flame length high. • GR6 – Dryland grass about 1-2 feet tall. Spread rate very high, flame length very high. • GR8 – Heavy, coarse, continuous grass 3-5 feet tall. Spread rate very high, flame length very high. • GR9 – Very heavy, coarse, continuous grass 5-8 feet tall. Spread rate extreme, flame length extreme. Mixture of grass and shrub, up to about 50% shrub coverage (grass/shrub) Arid to semiarid climate (rainfall deficient in summer). Extinction moisture content is 15%. • GS1 – Shrubs are about 1 foot high, low grass load. Spread rate moderate, flame length low. • GS2 – Shrubs are 1-3 feet high, moderate grass load. Spread rate high, flame length moderate. Subhumid to humid climate (rainfall adequate in all seasons). Extinction moisture content is 30-40%. • GS3 – Moderate grass/shrub load, average grass/shrub depth less than 2 feet. Spread rate high, flame length moderate. • GS4 – Heavy grass/shrub load, depth greater than 2 feet. Spread rate high, flame length very high.
Page 46
NWCG Guide for Wildland Fire Modules 43 of 77 Shrubs cover at least 50 percent of the site, grass sparse to nonexistent (shrub) Arid to semiarid climate (rainfall deficient in summer). Extinction moisture content is 15%. • SH1 – Low shrub load, fuel bed depth about 1 foot, some grass may be present. Spread rate very low, flame length very low. • SH2 – Moderate shrub load (higher than SH1), fuel bed depth about 1 foot, no grass present. Spread rate low to moderate, flame length low to moderate. • SH5 – Heavy shrub load, depth 4-6 feet. Spread rate very high, flame length very high. • SH7 – Very heavy shrub load, depth 4-6 feet. Spread rate lower than SH5, but similar flame length. Spread rate high, flame length very high. Subhumid to humid climate (rainfall adequate in all seasons). Extinction moisture content is 30-40%. • SH3 – Moderate shrub load, possibly with pine overstory or herbaceous fuel, fuel bed depth 2-3 feet. Spread rate low, flame length low. • SH4 – Low to moderate shrub and litter load, possibly with pine overstory, fuel bed depth about 3 feet. Spread rate high, flame length moderate. • SH6 – Dense shrubs, little, or no herb fuel, depth about 2 feet. Spread rate high, flame length high. • SH8 – Dense shrubs, little or no herb fuel, depth about 3 feet. Spread rate high, flame length high. • SH9 – Dense, finely branched shrubs with significant fine dead fuel, about 4-6 feet tall. Some herbaceous fuel may be present. Spread rate high, flame length very high. Grass or shrubs mixed with litter from forest canopy (timber/understory). Semiarid to subhumid climate. Extinction moisture content is 20%. • TU1 – Fuel bed is low load of grass and/or shrub with litter. Spread rate low, flame length low. • TU4 – Fuel bed is short conifer trees with grass or moss understory. Spread rate moderate, flame length moderate. • TU5 – Fuel bed is high load conifer litter with shrub understory. Spread rate moderate, flame length moderate. Humid climate. Extinction moisture content is 30%. • TU2 – Fuel bed is moderate litter load with shrub component. Spread rate moderate, flame length low. • TU3 – Fuel bed is moderate litter load with grass and shrub components. Spread rate high, flame length moderate. Dead and down woody fuel (litter) beneath a forest canopy (timber litter). Fuel bed is recently burned but able to carry wildland fire. • TL1 – Light to moderate load, fuels 1-2 inches deep. Spread rate very low, flame length very low.
Page 47
NWCG Guide for Wildland Fire Modules 44 of 77 Fuel bed composed of broadleaf (hardwood) litter. • TL2 – Low load, compact. Spread rate very low, flame length very low. • TL6 – Moderate load, less compact. Spread rate moderate, flame length low. • TL9 – Very high load, fluffy. Spread rate moderate, flame length moderate. Fuel bed composed of long-needle pine litter. • TL8 – Moderate load and compactness may include small amount of herbaceous load. Spread rate moderate, flame length low. Fuel bed not composed of broadleaf or long-needle pine litter. • TL3 – Moderate load conifer litter. Spread rate very low, flame length low. • TL4 – Moderate load, includes small diameter downed logs. Spread rate low, flame length low. • TL5 – High load conifer litter, light slash, or mortality fuel. Spread rate low, flame length low. • TL7 – Heavy load, includes larger diameter downed logs. Spread rate low, flame length low. • TL9 – Very high load broadleaf litter, heavy needle-drape in otherwise sparse shrub layer. Spread rate moderate, flame length moderate. Activity fuel or debris from wind damage (slash). Fuel bed is activity fuel. • SB1 – Fine fuel load is 10-20 tons per acre, weighted toward 1-3 inches diameter class. Depth is less than 1 foot. Spread rate moderate, flame length low. • SB2 – Fine fuel load is 7-12 tons per acre, evenly distributed across 0-0.25 inches diameter class. Spread rate moderate, flame length moderate. • SB3 – Fine fuel load is 7-12 tons per acre, weighted toward 0-0.25 inches diameter class. Depth is greater than 1 foot. Spread rate high, flame length high. Fuel bed is blowdown. • SB2 – Blowdown is scattered, with many trees still standing. Spread rate moderate, flame length moderate. • SB3 – Blowdown is moderate, trees compacted to near the ground. Spread rate high, flame length high. • SB4 – Blowdown is total, fuel bed not compacted, foliage still attached. Spread rate very high, flame length very high. Insufficient fuel to carry wildland fire under any condition (non-burnable). • NB1 – Urban or suburban development, insufficient fuel to carry wildland fire. • NB2 – Snow/ice. • NB3 – Agricultural field, maintained in non-burnable condition. • NB8 – Open water. • NB9 – Bare ground.
Page 48
NWCG Guide for Wildland Fire Modules 45 of 77 Relative Humidity and Dew Point Tables
Page 49
NWCG Guide for Wildland Fire Modules 46 of 77
Page 50
NWCG Guide for Wildland Fire Modules 47 of 77
Page 51
NWCG Guide for Wildland Fire Modules 48 of 77
Page 52
NWCG Guide for Wildland Fire Modules 49 of 77
Page 53
NWCG Guide for Wildland Fire Modules 50 of 77
Page 54
NWCG Guide for Wildland Fire Modules 51 of 77
Page 55
NWCG Guide for Wildland Fire Modules 52 of 77
Page 56
NWCG Guide for Wildland Fire Modules 53 of 77
Page 57
NWCG Guide for Wildland Fire Modules 54 of 77
Page 58
NWCG Guide for Wildland Fire Modules 55 of 77
Page 59
NWCG Guide for Wildland Fire Modules 56 of 77
Page 60
NWCG Guide for Wildland Fire Modules 57 of 77
Page 61
NWCG Guide for Wildland Fire Modules 58 of 77
Page 62
NWCG Guide for Wildland Fire Modules 59 of 77
Page 63
NWCG Guide for Wildland Fire Modules 60 of 77
Page 64
NWCG Guide for Wildland Fire Modules 61 of 77
Page 65
NWCG Guide for Wildland Fire Modules 62 of 77
Page 66
NWCG Guide for Wildland Fire Modules 63 of 77
Page 67
NWCG Guide for Wildland Fire Modules 64 of 77
Page 68
NWCG Guide for Wildland Fire Modules 65 of 77
Page 69
NWCG Guide for Wildland Fire Modules 66 of 77
Page 70
NWCG Guide for Wildland Fire Modules 67 of 77
Page 71
NWCG Guide for Wildland Fire Modules 68 of 77 Fine Dead Fuel Moisture Determining Below, Level, Above • B – Weather observations are taken between 1,000 and 2,000 feet ABOVE the fire behavior observations/projections. The fire is BELOW the weather site. • L – Weather observations are taken between 1,000 feet above and 1,000 feet below or LEVEL with the fire behavior observations/predictions. • A – Weather observations are taken between 1,000 and 2,000 feet BELOW the fire behavior observations/projections. The fire is ABOVE the weather site. How to choose from below/level/above for fuel moisture calculations
Page 72
NWCG Guide for Wildland Fire Modules 69 of 77 Determining Fine Dead Fuel Moisture • Reference fuel moisture (1) + fuel moisture correction (2E/2S) = fine dead fuel moisture (3E/3S). • 1 + 2E = 3E (exposed fuel moisture, less than 50% of fuels shaded by clouds/canopy). • 1 + 2S = 3S (shaded fuel moisture, greater than 50% of fuels shaded by clouds/canopy). • Before beginning: o What time is it? o What month is it? o Below, level, or above? Reference Fuel Moisture Day Time 0800 – 1959 1 Relative Humidity (%) Dry Bulb Temp (F) 0 – 4 5 – 9 10 – 14 15 – 19 20 – 24 25 - 29 30 – 34 35 - 39 40 – 44 45 – 49 50 – 54 55 – 59 60 – 64 65 – 69 70 – 74 75 – 79 80 – 84 85 – 89 90 – 94 95 – 99 100 10 – 29 1 2 2 3 4 5 5 6 7 8 8 8 9 9 10 11 12 12 13 13 14 30 – 49 1 2 2 3 4 5 5 6 7 7 7 8 9 9 10 10 11 12 13 13 13 50 – 69 1 2 2 3 4 5 5 6 6 7 7 8 8 9 9 10 11 12 12 12 13 70 – 89 1 1 2 2 3 4 5 5 6 7 7 8 8 8 9 10 10 11 12 12 13 90 – 109 1 1 2 2 3 4 5 5 6 7 7 8 8 8 9 10 10 11 12 12 13 109 + 1 1 2 2 3 4 4 5 6 7 7 8 8 8 9 10 10 11 12 12 12
Page 73
NWCG Guide for Wildland Fire Modules 70 of 77 Dead Fuel Moisture Content Corrections Feb Mar Apr Aug Sept Oct 2E EXPOSED Exposed – Less Than 50% Shading Of Surface Fuels Aspect Slope 0800 to 1000 to 1200 to 1400 to 1600 to 1800 to B L A B L A B L A B L A B L A B L A N 0 – 30% 3 4 5 1 2 3 1 1 2 1 1 2 1 2 3 3 4 5 31%+ 3 4 5 3 3 4 2 3 4 2 3 4 3 3 4 3 4 5 E 0 – 30% 3 4 5 1 2 3 1 1 1 1 1 2 1 2 3 3 4 5 31%+ 3 3 4 1 1 1 1 1 1 1 2 3 3 4 5 4 5 6 S 0 – 30% 3 4 5 1 2 2 1 1 1 1 1 1 1 2 3 3 4 5 31%+ 3 4 5 1 2 2 0 1 1 0 1 1 1 2 2 3 4 5 W 0 – 30% 3 4 5 1 2 3 1 1 1 1 1 1 1 2 3 3 4 5 31%+ 4 5 6 3 4 5 1 2 3 1 1 1 1 1 1 3 3 4 2S SHADED Shaded – Greater than or equal to 50% shading of surface fuels N All 4 5 6 4 5 5 3 4 5 3 4 5 4 5 5 4 5 6 E All 4 5 6 3 4 5 3 4 5 3 4 5 4 5 6 4 5 6 S All 4 5 6 3 4 5 3 4 5 3 4 5 3 4 5 4 5 6 W All 4 5 6 4 5 6 3 4 5 3 4 5 3 4 5 4 5 6 May June July 2E EXPOSED Exposed – Less than 50% shading of surface fuels Aspect Slope 0800 to 1000 to 1200 to 1400 to 1600 to 1800 to B L A B L A B L A B L A B L A B L A N 0 – 30% 2 3 4 1 1 1 0 0 1 0 0 1 1 1 1 2 3 4 31%+ 3 4 4 1 2 2 1 1 2 1 1 2 1 2 2 3 4 4 E 0 – 30% 2 2 3 1 1 1 0 0 1 0 0 1 1 1 2 3 4 4 31%+ 1 2 2 0 0 1 0 0 1 1 1 2 2 3 4 4 5 6 S 0 – 30% 2 3 3 1 1 1 0 0 1 0 0 1 1 1 1 2 3 3 31%+ 2 3 3 1 1 2 0 1 1 0 1 1 1 1 2 2 3 3 W 0 – 30% 2 3 4 1 1 2 0 0 1 0 0 1 0 1 1 2 3 3 31%+ 4 5 6 2 3 4 1 1 2 0 0 1 0 0 1 1 2 2 2S SHADED Shaded – Greater than or equal to 50% shading of surface fuels N All 4 5 5 3 4 5 3 3 4 3 3 4 3 4 5 4 5 5 E All 4 4 5 3 4 5 3 3 4 3 4 4 3 4 5 4 5 6 S All 4 4 5 3 4 5 3 3 4 3 3 4 3 4 5 4 5 6 W All 4 5 6 3 4 5 3 3 4 3 3 4 3 4 5 4 4 5
Page 74
NWCG Guide for Wildland Fire Modules 71 of 77 Nov Dec Jan 2E EXPOSED Exposed – Less than 50% shading of surface fuels Aspect Slope 0800 to 1000 to 1200 to 1400 to 1600 to 1800 to B L A B L A B L A B L A B L A B L A N 0 – 30% 4 5 6 3 4 5 2 3 4 2 3 4 3 4 5 4 5 6 31%+ 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 E 0 – 30% 4 5 6 3 4 4 2 3 3 2 3 3 3 4 5 4 5 6 31%+ 4 5 6 2 3 4 2 2 3 3 4 4 4 5 6 4 5 6 S 0 – 30% 4 5 6 3 4 5 2 3 3 2 2 3 3 4 4 4 5 6 31%+ 4 5 6 2 3 3 1 1 2 1 1 2 2 3 3 4 5 6 W 0 – 30% 4 5 6 3 4 5 2 3 3 2 3 3 3 4 4 4 5 6 31%+ 4 5 6 4 5 6 3 4 4 2 2 3 2 3 4 4 5 6 2S SHADED Shaded – Greater than or equal to 50% shading of surface fuels N All 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 E All 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 S All 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 W All 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6
Page 75
NWCG Guide for Wildland Fire Modules 72 of 77 Probability of Ignition Table
Page 76
NWCG Guide for Wildland Fire Modules 73 of 77 References Western Air Ambulance Phone List Phone numbers are not guaranteed to be current – be sure to double check! STATE SERVICE NAME HOSPITAL / LOCATION PHONE # Alaska MAST Alaska State Troopers 907-451-5333 Arizona Guardian Air Flagstaff Medical Center 800-523-9391 Intermountain Air Page 385-226-2860 California Mercy Air Ambulance Mercy Medical Center, Redding 866-480-5718 PHI Air Medical Redding 800-421-6111 Reach Air McClellan 916-921-4000 Colorado CareFlight of the Rockies Grand Junction 800-332-4923 AirLife Denver Denver 303-360-3400 Med Evac Greeley 800-247-5433 Guardian Flight Englewood 855-291-8989 Flight for Life St. Anthony’s, Denver 800-332-3123 Idaho Life Flight St. Alphonsus, Boise 800-232-0911 Life Flight Coeur d’Alene 800-232-0911 Victory Medical Flights Boise 208-321-1703 Montana Life Flight Missoula 800-232-0911 Mercy Flight Great Falls 800-972-4000 Medflight Billings 406-255-8411 Nevada Mercy Air Las Vegas 866-480-5718 Medical Air Service Reno 929-579-0653
Page 77
NWCG Guide for Wildland Fire Modules 74 of 77 Access Air Elko 775-738-3493 Care Flight Reno, Gardnerville, Truckee 775-858-5700 New Mexico Air Ambulance 1 Las Cruces 800-424-9000 Medical Flight Air Ambulance Albuquerque 505-842-4433 Lifeguard Air Emergency Albuquerque 505-272-3115 Gallup Med Flight Gallup 505-726-0053 Oregon AirLink Bend 800-621-5433 Life Flight Portland, Redmond, Salem 800-232-0911 Lifeguard Air Ambulance Hillsboro 503-640-2927 Utah Air Medical University of Utah Health Center, Salt Lake City 801-581-2500 Life Flight Intermountain Health Care, Salt Lake City 385-226-2860 Washington Life Flight Spokane 800-232-0911 Airlift Northwest Seattle 800-426-2430 Wyoming Wyoming Life Flight Wyoming Medical Center, Casper 800-442-2222 (Craig Dispatch)
Page 78
NWCG Guide for Wildland Fire Modules 75 of 77 Air to Ground Frequency Reference Map Radio frequencies may change over time. Always double check!
Page 79
NWCG Guide for Wildland Fire Modules 76 of 77 Slope
Page 80
NWCG Guide for Wildland Fire Modules 77 of 77 The NWCG Guide for Wildland Fire Modules is developed and maintained by the Fire Use Subcommittee (FUSC), under the direction of the Fuels Management Committee (FMC), an entity of the National Wildfire Coordinating Group (NWCG). Previous editions: 2022. While they may still contain current or useful information, previous editions are obsolete. The user of this information is responsible for confirming that they have the most up-to-date version. NWCG is the sole source for the publication. This publication is available electronically at https://www.nwcg.gov/publications/431. Printed copies may be ordered from the Great Basin Cache at the National Interagency Fire Center in Boise, Idaho. Refer to the annual NWCG NFES Catalog – Part 2: Publications, PMS 449-2, and ordering procedures at https://www.nwcg.gov/publications/nfes-catalogs. Submit comments, questions, and recommendations to the appropriate agency program manager assigned to the FUSC using the NWCG Publication Review Form, https://www.nwcg.gov/publications/publication-review-form. View the complete roster at https://www.nwcg.gov/committee/fire-use-subcommittee/roster. Publications and training materials produced by NWCG are in the public domain. Use of public domain information, including copying, is permitted. Use of NWCG information within another document is permitted if NWCG information is accurately credited to NWCG. The NWCG logo may not be used except on NWCG authorized information. “National Wildfire Coordinating Group,” “NWCG,” and the NWCG logo are trademarks of NWCG. The use of trade, firm, or corporation names or trademarks in NWCG products is solely for the information and convenience of the reader and does not constitute endorsement by NWCG or its member agencies of any product or service to the exclusion of others that may be suitable. This NWCG publication may contain links to information created and maintained by other non-federal public and/or private organizations. These organizations may have different policies from those of NWCG. Please note that NWCG does not control and cannot guarantee the relevance, timeliness, or accuracy of these outside materials.
- Markets
- Fire
- Topics
- leadership & practice
- Keywords
- fire, guide, leadership & practice, modules, nwcg, wildland
- Source checked by us
- Oct 5, 2026
- Source access
- Document retrieved
- Content delivery
- Hosted source copy
- Copy retrieved
- Oct 5, 2026
- Copy version
- 2025-05 · 0dbb26afa59f… (SHA-256)
An official publisher doesn't make a document mandatory everywhere: check applicability with your agency or issuer. Reading a resource, downloading a form or watching a video doesn't award certification or continuing-education credit; the issuer's own completion record does. The hosted copy is the publisher's file, unchanged; attribution is on this page, not added to the file.